530

High pressure steam sterilization goggles TL-GGLS

2021/4/17

1、 Product Introduction:
Regulatory basis;
New GMP: Personnel entering Zone A/B should wear protective goggles and describe the materials used. The goggles are made of high-temperature resistant synthetic plastic box silicone and the lens material is polycarbonate. (See Appendix 1, Article 24 for details)
New generation of high-performance sterile laboratory goggles. Ultra soft construction, lightweight, and polymer materials provide unparalleled comfort. High temperature and high-pressure sterilization clean function eye mask with indirect ventilation system, tempered and scratch resistant polycarbonate lenses, suitable for wearing glasses.


 

[Parameters of protective goggles]

Brand: Teling              Model: GGLS          Material: Lens (PC)

Origin: China              Grade: Level 1        Inspection: Individual Inspection

Frame (polymer material) assembly location: China Production environment: D-grade

Packaging type: Non sterile packaging Packaging specification: 10 packs/box
Packaging environment: D-grade Weight: 100g (ultra light)


 

[Performance of protective goggles]
1. Corrosion resistance: Therefore, the working environment of glasses is special, and they often come into contact with highly corrosive chemicals. Therefore, materials with good corrosion resistance, such as PC, must be used;
2. Impact resistance;
3. Good anti fog performance;
4. The breathability must be good, usually with breathable holes;
5. The internal space of the eye mask is large enough to be suitable for staff wearing nearsighted glasses.


 

[Instructions for protective goggles]
Please note during sterilization: The steam used for steam sterilization needs to be dry and clean. "Wet" steam contains suspended water droplets, which add condensation and are not helpful for the sterilization process. Dry steam is pure steam, and excessive condensation from wet steam can exceed the drying capacity of the steam sterilization cabinet. When sterilized items are removed, if they are not sufficiently cooled and contain humid and hot air, there may be water stains.
1. Sterilization temperature is 121 ℃.
2. Use deionized water or higher grade water for cleaning
3. Do not use disinfectants other than isopropanol and alcohol to disinfect the goggles. 4. During sterilization, do not let the goggles come into contact with other objects, especially those with high melting points, which can easily deform the frame. It is recommended to use a special sterilization bag to protect the goggles frame. Chinese characteristics: The silicone material has moderate hardness and is comfortable to wear. The frame shape is more in line with the face shape.